[{"data":1,"prerenderedAt":425},["ShallowReactive",2],{"blog-msl-floor-life-en":3,"header-nav-en":89},{"title":4,"description":5,"date":6,"lastUpdated":6,"category":7,"image":8,"readingTime":9,"wordCount":10,"timeRequired":11,"htmlContent":12,"tableOfContents":13,"tags":38,"slug":43,"jsonld":44},"Moisture-Sensitive Components: MSL Floor Life and Assembly Handoff","Track moisture-sensitive components and MSL floor life from receiving through reflow, and prepare exposure records for PCB assembly.","2026-11-17","assembly","",9,1792,"PT9M","\u003Cp>A moisture sensitivity level (MSL) helps an assembly team manage exposure of a particular component package through its final relevant reflow. The applicable requirements determine how storage and multiple passes are counted. The team needs the actual part and package label, a traceable exposure record, the applicable handling procedure and a plan for exceptions. A sealed bag or a successful electrical test alone does not tell the assembler how much floor life remains.\u003C\u002Fp>\n\u003Cp>This guide is for the person preparing a kit, accepting components or planning assembly. It addresses moisture-sensitive surface-mount devices; \u003Ca href=\"\u002Fen\u002Fblog\u002Fbare-pcb-storage-disposition\">bare PCB storage and disposition\u003C\u002Fa> addresses unassembled boards. The \u003Ca href=\"\u002Fen\u002Fblog\u002Fhow-to-avoid-bom-mismatch-and-substitution-risk-in-turnkey-pcba\">turnkey component substitution guide\u003C\u002Fa> covers a broader incoming-material and approval workflow; the question here is how to keep a specific lot&#39;s exposure history usable at the assembly line.\u003C\u002Fp>\n\u003Ch2 id=\"why-an-exposure-record-matters\" data-anchor-en=\"why-an-exposure-record-matters\">Why an exposure record matters\u003C\u002Fh2>\n\u003Cp>Some non-hermetic packages absorb moisture from the surrounding air. During rapid heating, that moisture can contribute to internal delamination, cracking or other damage. A visible bulge may indicate a problem, but the absence of visible damage or a passing electrical test does not establish that internal damage is absent. Moisture is one possible mechanism among several; an actual failure needs investigation.\u003C\u002Fp>\n\u003Cp>The relevant rating belongs to a particular component and package under stated classification conditions. Two parts with a similar outline do not necessarily share the same MSL, floor-life conditions or allowable thermal history. Record the manufacturer&#39;s part number and package along with the lot; do not substitute a rating from a visually similar device.\u003C\u002Fp>\n\u003Cp>IPC\u002FJEDEC J-STD-020 addresses moisture and reflow sensitivity classification. J-STD-033 addresses handling, packing, shipping and use. The applicable edition, the component maker&#39;s instructions and the agreed assembly procedure determine how a particular lot is handled. Confirm any conflict or missing information before using the parts.\u003C\u002Fp>\n\u003Ch2 id=\"separate-four-things-that-are-easy-to-confuse\" data-anchor-en=\"separate-four-things-that-are-easy-to-confuse\">Separate four things that are easy to confuse\u003C\u002Fh2>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Item\u003C\u002Fth>\n\u003Cth>What it addresses\u003C\u002Fth>\n\u003Cth>What to check\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>Sealed-package shelf life\u003C\u002Ftd>\n\u003Ctd>Time and storage conditions applicable while a device remains in its specified unopened packaging\u003C\u002Ftd>\n\u003Ctd>The actual label, seal date, supplier instructions and storage history; limits are not universal.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Floor life\u003C\u002Ftd>\n\u003Ctd>Exposure allowed for the device under the conditions stated by its applicable requirements before relevant reflow\u003C\u002Ftd>\n\u003Ctd>The specific part and package, recorded intervals, environmental conditions and approved handling procedure.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Classification reflow profile\u003C\u002Ftd>\n\u003Ctd>Conditions used to establish a device&#39;s moisture\u002Freflow classification\u003C\u002Ftd>\n\u003Ctd>Package classification temperature and manufacturer restrictions. It is not an oven recipe for every board.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Assembly reflow profile\u003C\u002Ftd>\n\u003Ctd>The thermal exposure the assembled board and its components actually experience\u003C\u002Ftd>\n\u003Ctd>The assembler&#39;s validated process, solder paste, board and components, plus any further reflow or rework.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>Shelf life is not a substitute for floor-life tracking. An opened bag with a seal date inside a supplier&#39;s stated shelf life can still have an incomplete exposure record. Nor does a component&#39;s classification automatically prove that the actual board profile, number of passes or rework conditions are acceptable.\u003C\u002Fp>\n\u003Ch2 id=\"at-receiving-identify-the-lot-before-opening-the-bag\" data-anchor-en=\"at-receiving-identify-the-lot-before-opening-the-bag\">At receiving: identify the lot before opening the bag\u003C\u002Fh2>\n\u003Cp>For each moisture-sensitive lot, match the manufacturer part number, package, quantity and lot identification against the approved order or kit record. Preserve the original label and applicable supplier documentation. Record the MSL, handling conditions and relevant reflow restrictions from the label and applicable component instructions, along with any available packing or seal date. Resolve missing information before use.\u003C\u002Fp>\n\u003Cp>Inspect the external package and its seal. A punctured bag, missing identification, apparently opened bag or disagreement between labels should trigger the agreed hold-and-notify process. Do not open an intact bag solely to read the humidity indicator unless the receiving procedure calls for it: opening can start or add exposure that must be managed.\u003C\u002Fp>\n\u003Cp>When the package is opened, inspect the humidity indicator and desiccant as required by the component supplier and applicable procedure. Record the result and opening time. A card indicates conditions according to its own use instructions; its color alone should not be treated as a universal acceptance rule. The presence of desiccant by itself also does not establish that the devices are fit for assembly.\u003C\u002Fp>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Incoming condition\u003C\u002Fth>\n\u003Cth>Immediate action\u003C\u002Fth>\n\u003Cth>Information to obtain before release\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>Sealed, identifiable bag\u003C\u002Ftd>\n\u003Ctd>Keep under specified conditions until needed; retain the label and receipt record.\u003C\u002Ftd>\n\u003Ctd>Applicable shelf-life and storage requirements.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Previously opened partial reel with complete records\u003C\u002Ftd>\n\u003Ctd>Link the part and lot to the recorded exposures and storage intervals.\u003C\u002Ftd>\n\u003Ctd>Whether the procedure accepts those records and how to calculate remaining exposure.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Unknown opening time or damaged seal\u003C\u002Ftd>\n\u003Ctd>Place the affected material on hold; tell the owner or supplier.\u003C\u002Ftd>\n\u003Ctd>Disposition from the responsible quality authority and component maker where needed.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Missing MSL or mismatched identification\u003C\u002Ftd>\n\u003Ctd>Segregate the lot rather than borrow a rating from a similar part.\u003C\u002Ftd>\n\u003Ctd>Confirmed part, package, label and handling instructions.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>For customer-supplied components, agree who owns that disposition and whether the assembler may perform corrective processing. See \u003Ca href=\"\u002Fen\u002Fblog\u002Fturnkey-vs-consigned-pcb-assembly\">turnkey vs. consigned assembly\u003C\u002Fa> for the wider division of sourcing and material responsibility.\u003C\u002Fp>\n\u003Ch2 id=\"work-out-the-remaining-exposure-from-the-record\" data-anchor-en=\"work-out-the-remaining-exposure-from-the-record\">Work out the remaining exposure from the record\u003C\u002Fh2>\n\u003Cp>The following example is a \u003Cstrong>hypothetical accounting exercise\u003C\u002Fstrong>, not an allowance for a real device. Assume a specific component&#39;s applicable label and procedure permit 168 hours under compliant environmental conditions, not specified here. Assume both recorded intervals count in full under that procedure, with no unrecorded exposure. Dry storage between them is acceptable only under the conditions and rules in the approved procedure.\u003C\u002Fp>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Recorded step\u003C\u002Fth>\n\u003Cth align=\"right\">Exposure to count\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>First eligible interval after opening\u003C\u002Ftd>\n\u003Ctd align=\"right\">48 hours\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Second eligible interval after approved storage\u003C\u002Ftd>\n\u003Ctd align=\"right\">36 hours\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Total counted exposure\u003C\u002Ftd>\n\u003Ctd align=\"right\">48 + 36 = 84 hours\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Nominal remaining allowance\u003C\u002Ftd>\n\u003Ctd align=\"right\">168 - 84 = 84 hours\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>The result is useful only if the label, conditions, time records and treatment of storage all apply to this lot. A temperature or humidity excursion, missing interval, uncertain storage condition or different label leaves this simple calculation unverified until assessed against the applicable requirements. Hold the lot for a documented disposition instead of guessing how many hours remain. The actual process must account for the time through the final relevant reflow, including intervals between assembly passes when applicable.\u003C\u002Fp>\n\u003Cp>Mark partial reels, trays and split lots so the remaining quantity stays linked to its own record. A transfer between sites or suppliers needs the same information, not just a statement that the parts were &quot;stored dry.&quot;\u003C\u002Fp>\n\u003Ch2 id=\"repackaging-drying-and-rework-need-separate-decisions\" data-anchor-en=\"repackaging-drying-and-rework-need-separate-decisions\">Repackaging, drying and rework need separate decisions\u003C\u002Fh2>\n\u003Cp>Resealing a bag is a packaging action. It does not, by itself, establish a new full floor-life allowance. An approved dry-storage or drying process may change how exposure is accounted for, but the conditions, duration and record treatment must follow the applicable requirements and component instructions. Keep the previous exposure history and the action taken with the lot.\u003C\u002Fp>\n\u003Cp>If exposure is exceeded or uncertain, the responsible team should determine whether the components can be dried or need another disposition. Do not apply a generic bake temperature and duration: package construction, prior exposure, carrier material and supplier instructions matter. A reel, tape, tray or tube suitable for normal handling may not tolerate the proposed process. Moving devices to another carrier also creates identification, traceability and handling risks. Record any authorized processing and its release decision.\u003C\u002Fp>\n\u003Cp>Double-sided assembly and later rework add another handoff. A device already mounted on the first side may be exposed again before a later thermal cycle. Other components, board materials and finishes also constrain a rework or drying decision. Agree on the planned passes, elapsed time, storage and any rework requirements before assembly; do not assume a bare-board process is interchangeable with a populated-board process. The \u003Ca href=\"\u002Fen\u002Fblog\u002Freflow-profile-basics\">reflow profile basics guide\u003C\u002Fa> explains the broader oven-profile discussion.\u003C\u002Fp>\n\u003Ch2 id=\"what-should-a-kit-or-assembly-handoff-contain\" data-anchor-en=\"what-should-a-kit-or-assembly-handoff-contain\">What should a kit or assembly handoff contain?\u003C\u002Fh2>\n\u003Cp>Send the assembler a lot-specific record that can be checked against the physical material:\u003C\u002Fp>\n\u003Col>\n\u003Cli>Manufacturer part number, package, quantity and lot or traceability identifier.\u003C\u002Fli>\n\u003Cli>MSL, relevant conditions and component-maker handling and reflow restrictions, with their sources.\u003C\u002Fli>\n\u003Cli>Seal date and packaging status where available, plus any receiving discrepancy.\u003C\u002Fli>\n\u003Cli>Opening times, eligible exposure intervals, environmental conditions and approved storage intervals.\u003C\u002Fli>\n\u003Cli>Remaining allowance or a clear &quot;unknown \u002F on hold&quot; status, with the calculation and assumptions.\u003C\u002Fli>\n\u003Cli>Any authorized drying, repackaging, split-lot transfer or other disposition, with dates and traceable records.\u003C\u002Fli>\n\u003Cli>Intended assembly passes, rework expectations and the contact authorized to resolve discrepancies.\u003C\u002Fli>\n\u003C\u002Fol>\n\u003Cp>Agree on what happens when the delivered quantity differs from the record, the label is unreadable or the line cannot complete the planned pass within the remaining allowance. The team should know who can authorize a disposition and whether replacements are available before the job is released. Resolving these questions early can prevent a line stop without treating missing evidence as an acceptance.\u003C\u002Fp>\n\u003Cp>APTPCB offers PCB fabrication and \u003Ca href=\"\u002Fen\u002Fpcba\u002Fturnkey-assembly\">turnkey PCB assembly\u003C\u002Fa>. For a project quote, supply the \u003Ca href=\"\u002Fen\u002Fblog\u002Fhow-to-prepare-bom-for-turnkey-pcb-assembly\">assembly BOM\u003C\u002Fa>, identify consigned and partially used lots, and flag parts with short or uncertain remaining exposure. Ask what handling and documentation can be provided for the job. Request project-specific support through the \u003Ca href=\"\u002Fen\u002Fquote\">quote page\u003C\u002Fa> or \u003Ca href=\"\u002Fen\u002Fcontact\">contact the team\u003C\u002Fa>.\u003C\u002Fp>\n\u003Cdiv data-component=\"BlogQuickQuoteInline\">\u003C\u002Fdiv>\n\n\u003C!-- faq:start -->\n\u003Ch2 id=\"frequently-asked-questions\" data-anchor-en=\"frequently-asked-questions\">Frequently asked questions\u003C\u002Fh2>\n\u003Ch3 id=\"does-an-intact-sealed-bag-prove-that-the-components-are-ready-to-use\" data-anchor-en=\"does-an-intact-sealed-bag-prove-that-the-components-are-ready-to-use\">Does an intact sealed bag prove that the components are ready to use?\u003C\u002Fh3>\n\u003Cp>No. Check identification, applicable storage and shelf-life conditions, labels and the required receiving evidence. A sealed bag cannot by itself establish that all preceding storage conditions were met.\u003C\u002Fp>\n\u003Ch3 id=\"does-resealing-a-partial-reel-reset-its-floor-life\" data-anchor-en=\"does-resealing-a-partial-reel-reset-its-floor-life\">Does resealing a partial reel reset its floor life?\u003C\u002Fh3>\n\u003Cp>Do not assume so. Record the exposure and use the approved storage or drying procedure and the device manufacturer&#39;s instructions to determine the status after repackaging.\u003C\u002Fp>\n\u003Ch3 id=\"can-visual-inspection-or-a-functional-test-replace-the-exposure-record\" data-anchor-en=\"can-visual-inspection-or-a-functional-test-replace-the-exposure-record\">Can visual inspection or a functional test replace the exposure record?\u003C\u002Fh3>\n\u003Cp>No. Those checks can provide useful evidence but do not reconstruct exposure history or rule out internal damage. Follow the agreed disposition procedure when records are missing or exposure is uncertain.\u003C\u002Fp>\n\u003Ch3 id=\"is-the-component39s-classification-temperature-the-correct-oven-setting\" data-anchor-en=\"is-the-components-classification-temperature-the-correct-oven-setting\">Is the component&#39;s classification temperature the correct oven setting?\u003C\u002Fh3>\n\u003Cp>No. The classification profile is used to classify a device&#39;s moisture and reflow sensitivity. The assembly profile must be established for the actual board, components, paste and process without exceeding applicable device limits.\u003C\u002Fp>\n\u003C!-- faq:end -->\n\n\u003Ch2 id=\"technical-references\" data-anchor-en=\"technical-references\">Technical references\u003C\u002Fh2>\n\u003Cul>\n\u003Cli>Texas Instruments, \u003Ca href=\"https:\u002F\u002Fwww.ti.com\u002Flit\u002Fan\u002Fslva840\u002Fslva840.pdf\">\u003Cem>Power Module MSL Ratings and Reflow Ratings\u003C\u002Fem>\u003C\u002Fa>, SLVA840: an example of MSL and reflow information for TI power modules; it references earlier standard editions and its examples must not be generalized to every device.\u003C\u002Fli>\n\u003Cli>Texas Instruments, \u003Ca href=\"https:\u002F\u002Fwww.ti.com\u002Flit\u002Fan\u002Fsnoa550\u002Fsnoa550.pdf\">\u003Cem>AN-2029 Handling and Process Recommendations\u003C\u002Fem>\u003C\u002Fa>, SNOA550H: TI-specific storage, handling and reflow considerations; use the applicable instructions for the actual part.\u003C\u002Fli>\n\u003C\u002Ful>\n\n\u003Csection class=\"related-links\" aria-label=\"Related\">\u003Ch3>Related links\u003C\u002Fh3>\u003Cul>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fbare-pcb-storage-disposition\">bare PCB storage and disposition\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fhow-to-avoid-bom-mismatch-and-substitution-risk-in-turnkey-pcba\">turnkey component substitution guide\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fturnkey-vs-consigned-pcb-assembly\">turnkey vs. consigned assembly\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Freflow-profile-basics\">reflow profile basics guide\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fpcba\u002Fturnkey-assembly\">turnkey PCB assembly\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fhow-to-prepare-bom-for-turnkey-pcb-assembly\">assembly BOM\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fquote\">quote page\u003C\u002Fa>\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fsection>",[14,17,20,23,26,29,32,35],{"id":15,"text":16},"why-an-exposure-record-matters","Why an exposure record matters",{"id":18,"text":19},"separate-four-things-that-are-easy-to-confuse","Separate four things that are easy to confuse",{"id":21,"text":22},"at-receiving-identify-the-lot-before-opening-the-bag","At receiving: identify the lot before opening the bag",{"id":24,"text":25},"work-out-the-remaining-exposure-from-the-record","Work out the remaining exposure from the record",{"id":27,"text":28},"repackaging-drying-and-rework-need-separate-decisions","Repackaging, drying and rework need separate decisions",{"id":30,"text":31},"what-should-a-kit-or-assembly-handoff-contain","What should a kit or assembly handoff contain?",{"id":33,"text":34},"frequently-asked-questions","Frequently asked questions",{"id":36,"text":37},"technical-references","Technical references",[39,40,41,42],"moisture sensitive devices","MSL","floor life","PCB assembly","msl-floor-life",{"blog":45,"breadcrumb":54,"faq":68},{"@context":46,"@type":47,"headline":4,"description":5,"url":48,"datePublished":6,"dateModified":6,"timeRequired":11,"keywords":49,"articleSection":7,"author":50,"publisher":53},"https:\u002F\u002Fschema.org","BlogPosting","https:\u002F\u002Faptpcb.com\u002Fen\u002Fblog\u002Fmsl-floor-life","moisture sensitive devices, MSL, floor life, PCB assembly",{"@type":51,"name":52},"Organization","APTPCB",{"@type":51,"name":52},{"@context":46,"@type":55,"itemListElement":56},"BreadcrumbList",[57,62,66],{"@type":58,"position":59,"name":60,"item":61},"ListItem",1,"Home","https:\u002F\u002Faptpcb.com\u002F",{"@type":58,"position":63,"name":64,"item":65},2,"Blog","https:\u002F\u002Faptpcb.com\u002Fen\u002Fblog",{"@type":58,"position":67,"name":43,"item":48},3,{"@context":46,"@type":69,"mainEntity":70},"FAQPage",[71,77,81,85],{"@type":72,"name":73,"acceptedAnswer":74},"Question","Does an intact sealed bag prove that the components are ready to use?",{"@type":75,"text":76},"Answer","No. Check identification, applicable storage and shelf-life conditions, labels and the required receiving evidence. A sealed bag cannot by itself establish that all preceding storage conditions were met.",{"@type":72,"name":78,"acceptedAnswer":79},"Does resealing a partial reel reset its floor life?",{"@type":75,"text":80},"Do not assume so. Record the exposure and use the approved storage or drying procedure and the device manufacturer's instructions to determine the status after repackaging.",{"@type":72,"name":82,"acceptedAnswer":83},"Can visual inspection or a functional test replace the exposure record?",{"@type":75,"text":84},"No. Those checks can provide useful evidence but do not reconstruct exposure history or rule out internal damage. Follow the agreed disposition procedure when records are missing or exposure is uncertain.",{"@type":72,"name":86,"acceptedAnswer":87},"Is the component's classification temperature the correct oven setting?",{"@type":75,"text":88},"No. The classification profile is used to classify a device's moisture and reflow sensitivity. The assembly profile must be established for the actual board, components, paste and process without exceeding applicable device limits.",{"pcbManufacturingColumns":90,"capabilityColumns":218,"resourceColumns":254,"pcbaColumns":298},[91,139,168,197],{"heading":92,"links":93},"PCB Product Families",[94,97,100,103,106,109,112,115,118,121,124,127,130,133,136],{"label":95,"path":96},"FR-4 PCB","\u002Fpcb\u002Ffr4-pcb",{"label":98,"path":99},"High-Speed PCB","\u002Fpcb\u002Fhigh-speed-pcb",{"label":101,"path":102},"Multilayer PCB","\u002Fpcb\u002Fmultilayer-pcb",{"label":104,"path":105},"HDI PCB","\u002Fpcb\u002Fhdi-pcb",{"label":107,"path":108},"Flexible PCB","\u002Fpcb\u002Fflex-pcb",{"label":110,"path":111},"Rigid Flex PCB","\u002Fpcb\u002Frigid-flex-pcb",{"label":113,"path":114},"Ceramic PCB","\u002Fpcb\u002Fceramic-pcb",{"label":116,"path":117},"Heavy Copper PCB","\u002Fpcb\u002Fheavy-copper-pcb",{"label":119,"path":120},"High Thermal PCB","\u002Fpcb\u002Fhigh-thermal-pcb",{"label":122,"path":123},"Antenna PCB","\u002Fpcb\u002Fantenna-pcb",{"label":125,"path":126},"High Frequency PCB","\u002Fpcb\u002Fhigh-frequency-pcb",{"label":128,"path":129},"Microwave PCB","\u002Fpcb\u002Fmicrowave-pcb",{"label":131,"path":132},"Metal Core PCB","\u002Fpcb\u002Fmetal-core-pcb",{"label":134,"path":135},"High-Tg PCB","\u002Fpcb\u002Fhigh-tg-pcb",{"label":137,"path":138},"Backplane PCB","\u002Fpcb\u002Fbackplane-pcb",{"sections":140},[141],{"heading":142,"links":143},"RF & Materials",[144,147,150,153,156,159,162,165],{"label":145,"path":146},"Rogers PCB","\u002Fmaterials\u002Frf-rogers",{"label":148,"path":149},"Taconic PCB","\u002Fmaterials\u002Ftaconic-pcb",{"label":151,"path":152},"Teflon PCB","\u002Fmaterials\u002Fteflon-pcb",{"label":154,"path":155},"Arlon PCB","\u002Fmaterials\u002Farlon-pcb",{"label":157,"path":158},"Megtron PCB","\u002Fmaterials\u002Fmegtron-pcb",{"label":160,"path":161},"ISOLA PCB","\u002Fmaterials\u002Fisola-pcb",{"label":163,"path":164},"Spread Glass FR-4","\u002Fmaterials\u002Fspread-glass-fr4",{"label":166,"path":167},"Impedance Control","\u002Fpcb\u002Fpcb-impedance-control",{"sections":169},[170],{"heading":171,"links":172},"Manufacturing \u002F Stackups",[173,176,179,182,185,188,191,194],{"label":174,"path":175},"Quickturn Prototypes","\u002Fpcb\u002Fquick-turn-pcb",{"label":177,"path":178},"NPI & Small Batch (PCB)","\u002Fpcb\u002Fnpi-small-batch-pcb-manufacturing",{"label":180,"path":181},"High-Volume Production","\u002Fpcb\u002Fmass-production-pcb-manufacturing",{"label":183,"path":184},"High Layer Count PCB","\u002Fpcb\u002Fhigh-layer-count-pcb",{"label":186,"path":187},"PCB Fabrication Process","\u002Fpcb\u002Fpcb-fabrication-process",{"label":189,"path":190},"Advanced PCB Manufacturing","\u002Fpcb\u002Fadvanced-pcb-manufacturing",{"label":192,"path":193},"Special PCB Manufacturing","\u002Fpcb\u002Fspecial-pcb-manufacturing",{"label":195,"path":196},"Multi-Layer Laminated Structure","\u002Fpcb\u002Fmultilayer-pcb-lamination-services",{"heading":198,"links":199},"Specialties & Resources",[200,203,206,209,212,215],{"label":201,"path":202},"PCB Design & Layout Services","\u002Fpcba\u002Fpcb-design-services",{"label":204,"path":205},"PCB Surface Finishes","\u002Fpcb\u002Fpcb-surface-finishes",{"label":207,"path":208},"PCB Drilling & Vias","\u002Fpcb\u002Fpcb-drilling",{"label":210,"path":211},"PCB Stackup","\u002Fpcb\u002Fpcb-stack-up",{"label":213,"path":214},"PCB Profiling","\u002Fpcb\u002Fpcb-profiling",{"label":216,"path":217},"Quality & Inspection","\u002Fpcb\u002Fpcb-quality",[219,224,229,234,239,244,249],{"links":220},[221],{"label":222,"path":223},"Rigid PCB Capability","\u002Fcapabilities\u002Frigid-pcb",{"links":225},[226],{"label":227,"path":228},"Rigid-Flex Capability","\u002Fcapabilities\u002Frigid-flex-pcb",{"links":230},[231],{"label":232,"path":233},"Flex PCB Capability","\u002Fcapabilities\u002Fflex-pcb",{"links":235},[236],{"label":237,"path":238},"HDI PCB Capability","\u002Fcapabilities\u002Fhdi-pcb",{"links":240},[241],{"label":242,"path":243},"Metal PCB Capability","\u002Fcapabilities\u002Fmetal-pcb",{"links":245},[246],{"label":247,"path":248},"Ceramic PCB Capability","\u002Fcapabilities\u002Fceramic-pcb",{"links":250},[251],{"label":252,"path":253},"Heavy Copper PCB Capability","\u002Fcapabilities\u002Fheavy-copper-pcb",[255,266,290],{"heading":256,"links":257},"Downloads",[258,261,264],{"label":259,"path":260},"Materials Datasheet \u002F Processing Notes","\u002Fresources\u002Fdownloads-materials",{"label":262,"path":263},"PCB DFM Guidelines","\u002Fresources\u002Fdfm-guidelines",{"label":195,"path":265},"\u002Fpcb\u002Fmulti-layer-laminated-structure",{"heading":267,"links":268},"Tools",[269,272,275,278,281,284,287],{"label":270,"path":271},"Gerber Viewer","\u002Ftools\u002Fgerber-viewer",{"label":273,"path":274},"PCB Viewer","\u002Ftools\u002Fpcb-viewer",{"label":276,"path":277},"BOM Viewer","\u002Ftools\u002Fbom-viewer",{"label":279,"path":280},"3D Viewer","\u002Ftools\u002F3d-viewer",{"label":282,"path":283},"Circuit Simulator","\u002Ftools\u002Fcircuit-simulator",{"label":285,"path":286},"Impedance Calculator","\u002Ftools\u002Fimpedance-calculator",{"label":288,"path":289},"Trace Width Calculator","\u002Ftools\u002Ftrace-width-calculator",{"heading":291,"links":292},"FAQ & Blog",[293,296],{"label":294,"path":295},"FAQ","\u002Fresources\u002Ffaq",{"label":64,"path":297},"\u002Fblog",[299,329,355,388],{"heading":300,"links":301},"Core Services",[302,305,308,311,314,317,320,323,326],{"label":303,"path":304},"Turnkey PCB Assembly","\u002Fpcba\u002Fturnkey-assembly",{"label":306,"path":307},"NPI & Small Batch PCB Assembly","\u002Fpcba\u002Fnpi-assembly",{"label":309,"path":310},"Mass Production PCB Assembly","\u002Fpcba\u002Fmass-production",{"label":312,"path":313},"Flex & Rigid-Flex PCB Assembly","\u002Fpcba\u002Fflex-rigid-flex",{"label":315,"path":316},"SMT & Through-Hole Assembly","\u002Fpcba\u002Fsmt-tht",{"label":318,"path":319},"BGA PCB Assembly","\u002Fpcba\u002Fbga-qfn-fine-pitch",{"label":321,"path":322},"Components & BOM Management","\u002Fpcba\u002Fcomponents-bom",{"label":324,"path":325},"Box Build Assembly","\u002Fpcba\u002Fbox-build-assembly",{"label":327,"path":328},"PCB Assembly Testing & Quality","\u002Fpcba\u002Ftesting-quality",{"heading":330,"links":331},"Supporting Services",[332,334,337,340,343,346,349,352],{"label":333,"path":202},"PCB Design & Layout",{"label":335,"path":336},"Every Support Touchpoint","\u002Fpcba\u002Fsupport-services",{"label":338,"path":339},"Stencil Lab","\u002Fpcba\u002Fpcb-stencil",{"label":341,"path":342},"Components Sourcing","\u002Fpcba\u002Fcomponent-sourcing",{"label":344,"path":345},"IC Programming","\u002Fpcba\u002Fic-programming",{"label":347,"path":348},"Conformal Coating","\u002Fpcba\u002Fpcb-conformal-coating",{"label":350,"path":351},"Selective Soldering","\u002Fpcba\u002Fpcb-selective-soldering",{"label":353,"path":354},"BGA Reballing","\u002Fpcba\u002Fbga-reballing",{"heading":356,"links":357},"Quality & Testing",[358,361,364,367,370,373,376,379,382,385],{"label":359,"path":360},"Quality Inspection","\u002Fpcba\u002Fquality-system",{"label":362,"path":363},"First Article Inspection (FAI)","\u002Fpcba\u002Ffirst-article-inspection",{"label":365,"path":366},"Solder Paste Inspection (SPI)","\u002Fpcba\u002Fspi-inspection",{"label":368,"path":369},"AOI Optical Inspection","\u002Fpcba\u002Faoi-inspection",{"label":371,"path":372},"X-Ray \u002F CT Inspection","\u002Fpcba\u002Fxray-inspection",{"label":374,"path":375},"ICT In-Circuit Testing","\u002Fpcba\u002Fict-test",{"label":377,"path":378},"Flying Probe Testing","\u002Fpcba\u002Fflying-probe-testing",{"label":380,"path":381},"FCT \u002F Functional Testing","\u002Fpcba\u002Ffct-test",{"label":383,"path":384},"Final Inspection & Packing","\u002Fpcba\u002Ffinal-quality-inspection",{"label":386,"path":387},"Incoming Quality Control","\u002Fpcba\u002Fincoming-quality-control",{"heading":389,"linkClass":390,"links":391},"Industry Applications (Entry)","text-nowrap",[392,395,398,401,404,407,410,413,416,419,422],{"label":393,"path":394},"Server \u002F Data Center","\u002Findustries\u002Fserver-data-center-pcb",{"label":396,"path":397},"Automotive \u002F EV","\u002Findustries\u002Fautomotive-electronics-pcb",{"label":399,"path":400},"Medical","\u002Findustries\u002Fmedical-pcb",{"label":402,"path":403},"Telecom \u002F 5G","\u002Findustries\u002Fcommunication-equipment-pcb",{"label":405,"path":406},"Aerospace & Defense","\u002Findustries\u002Faerospace-defense-pcb",{"label":408,"path":409},"Drone \u002F UAV","\u002Findustries\u002Fdrone-uav-pcb",{"label":411,"path":412},"Industrial Control & Automation","\u002Findustries\u002Findustrial-control-pcb",{"label":414,"path":415},"Power & New Energy","\u002Findustries\u002Fpower-energy-pcb",{"label":417,"path":418},"Robotics & Automation","\u002Findustries\u002Frobotics-pcb",{"label":420,"path":421},"Security \u002F Security Equipment","\u002Findustries\u002Fsecurity-equipment-pcb",{"label":423,"path":424},"PCB Industry Overview →","\u002Fpcb-industry-solutions",1794926066283]