[{"data":1,"prerenderedAt":421},["ShallowReactive",2],{"blog-pcb-panel-x-outs-en":3,"header-nav-en":85},{"title":4,"description":5,"date":6,"lastUpdated":6,"category":7,"image":8,"readingTime":9,"wordCount":10,"timeRequired":11,"htmlContent":12,"tableOfContents":13,"tags":38,"slug":43,"jsonld":44},"PCB Panel X-Outs: How to Specify, Receive and Assemble Panels","Set PCB panel X-out acceptance terms, identify rejected positions, verify assembly skips and reconcile usable board quantities.","2026-11-17","assembly","",10,1873,"PT10M","\u003Cp>An X-out is an individual PCB position in a panel that has been identified as unacceptable and excluded from use. The surrounding panel may still be useful, but only if the buyer, fabricator and assembler agree on which positions are excluded and how every relevant operation will handle them.\u003C\u002Fp>\n\u003Cp>The \u003Ca href=\"\u002Fen\u002Fblog\u002Fpanelization-for-assembly\">panelization for assembly guide\u003C\u002Fa> covers the wider design of an assembly array. This article focuses on a narrower question: how to order and receive a panel with rejected positions without accidentally building them or miscounting the boards you need.\u003C\u002Fp>\n\u003Cp>An X mark tells you to exclude that position; it does not explain every defect or prove that unmarked boards passed electrical testing. Ask for the inspection and test evidence required by your order. Nor does an X-out automatically mean a board has been repaired or is suitable for use.\u003C\u002Fp>\n\u003Ch2 id=\"decide-the-acceptance-policy-before-fabrication\" data-anchor-en=\"decide-the-acceptance-policy-before-fabrication\">Decide the acceptance policy before fabrication\u003C\u002Fh2>\n\u003Cp>Choose a policy with both the board supplier and the assembler before placing the order. A fabricator may be able to deliver an array that the assembly line cannot reliably process. Conversely, a no-X-out requirement can affect the supplier&#39;s manufacturing and delivery options; request project-specific quotes rather than assuming a saving or premium.\u003C\u002Fp>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Policy\u003C\u002Fth>\n\u003Cth>What to specify\u003C\u002Fth>\n\u003Cth>When to discuss it\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>No X-outs\u003C\u002Ftd>\n\u003Ctd>No rejected positions in delivered panels; define how shortages or deviations will be handled.\u003C\u002Ftd>\n\u003Ctd>When the customer specification prohibits them or the assembly process cannot control individual skips.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>X-outs allowed within agreed limits\u003C\u002Ftd>\n\u003Ctd>Maximum rejected positions per panel and per lot or shipment, the denominator for each limit, marking, identification and handling.\u003C\u002Ftd>\n\u003Ctd>When the full manufacturing and assembly chain can identify and exclude them.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Deviation requires approval\u003C\u002Ftd>\n\u003Ctd>What triggers a hold, who can approve it and whether shipment may proceed.\u003C\u002Ftd>\n\u003Ctd>When a proposed exception needs a case-by-case quality decision.\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>There is no single allowance to insert into every purchase order. For example, NCAB&#39;s published specification states a no-X-out policy, while PCBasic describes its own X-out ordering options. Neither is automatically the rule for another supplier or project. If your customer, drawing or contract requires no X-outs, a mark does not override that requirement.\u003C\u002Fp>\n\u003Cp>Limits should also address distribution. An allowance for a whole shipment does not by itself say how many rejected positions can occur in one panel. Define whether partial or replacement panels are acceptable and what happens when the limit is exceeded.\u003C\u002Fp>\n\u003Ch2 id=\"agree-on-a-mark-and-a-position-map\" data-anchor-en=\"agree-on-a-mark-and-a-position-map\">Agree on a mark and a position map\u003C\u002Fh2>\n\u003Cp>A human-readable X, a mark for a vision system and a digital map may serve different purposes. A large visible X is not automatically recognizable by a particular machine. Confirm the intended method with the actual assembler and equipment, then document:\u003C\u002Fp>\n\u003Col>\n\u003Cli>\u003Cstrong>Panel identity and revision:\u003C\u002Fstrong> board part number, panel drawing revision, lot and a panel identifier wherever the process uses panel-specific maps.\u003C\u002Fli>\n\u003Cli>\u003Cstrong>Position scheme:\u003C\u002Fstrong> reference side and view, origin, row and column labels, feed direction, and how rotations and flips are represented.\u003C\u002Fli>\n\u003Cli>\u003Cstrong>Physical mark:\u003C\u002Fstrong> location within the rejected board, size, contrast, material, sides and any reserved area required by the receiving process. Agree on material compatibility; do not cover needed fiducials, test features or identification unless the approved procedure specifically calls for it.\u003C\u002Fli>\n\u003Cli>\u003Cstrong>Map and control:\u003C\u002Fstrong> which panel each map belongs to, the rejected positions, file format, revision, transmission method and the person responsible for updates.\u003C\u002Fli>\n\u003Cli>\u003Cstrong>Receiving evidence:\u003C\u002Fstrong> required segregation, package identification and the agreed inspection or test records for the remaining positions.\u003C\u002Fli>\n\u003C\u002Fol>\n\u003Cp>An electronic map is useful only if it is associated with the correct physical panel and interpreted in the correct orientation. Agree whether the physical mark, map or both are required, how they are checked, and who resolves a disagreement. A panel-level identifier must remain legible through the operations that rely on it. The broader \u003Ca href=\"\u002Fen\u002Fblog\u002Fpcb-traceability-lot-control\">lot traceability guide\u003C\u002Fa> explains why lot records matter; a lot number alone does not identify a rejected position within a particular panel.\u003C\u002Fp>\n\u003Ch2 id=\"a-worked-handoff-for-a-12-position-panel\" data-anchor-en=\"a-worked-handoff-for-a-12-position-panel\">A worked handoff for a 12-position panel\u003C\u002Fh2>\n\u003Cp>In this \u003Cstrong>hypothetical example\u003C\u002Fstrong>, the approved panel drawing has three rows and four columns. Looking at the \u003Cstrong>top side\u003C\u002Fstrong>, with the drawing&#39;s labelled top edge away from the viewer, rows A to C run from top to bottom and columns 1 to 4 from left to right. Panel \u003Ccode>P017\u003C\u002Fcode> has one excluded bare-board position, \u003Ccode>A2\u003C\u002Fcode>:\u003C\u002Fp>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Top-side view\u003C\u002Fth>\n\u003Cth>Column 1\u003C\u002Fth>\n\u003Cth>Column 2\u003C\u002Fth>\n\u003Cth>Column 3\u003C\u002Fth>\n\u003Cth>Column 4\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>Row A\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>\u003Cstrong>X-out A2\u003C\u002Fstrong>\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Row B\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Row C\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003Ctd>Available\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>For this example, the agreed method requires both a physical mark and a map. The map accompanying \u003Ccode>P017\u003C\u002Fcode> identifies \u003Ccode>A2\u003C\u002Fcode> as rejected and references the panel drawing revision. With the required acceptance evidence for the other positions, this panel contributes \u003Cstrong>11 accepted bare boards\u003C\u002Fstrong>. It does not promise 11 accepted finished assemblies: placement, soldering, test or later handling may introduce additional losses.\u003C\u002Fp>\n\u003Cp>Suppose the panel is turned over around its vertical axis, while the labelled top edge remains away from the viewer. In a bottom-side view whose columns are again counted left to right, the same physical \u003Ccode>A2\u003C\u002Fcode> position appears at row A, column 3. Record it as \u003Cstrong>top-view A2 = bottom-view A3 under this defined flip\u003C\u002Fstrong>, and verify it against the actual panel and bottom-side program. If the assembler uses another origin, numbering scheme or rotation, this conversion changes. The label alone is not enough to program a skip.\u003C\u002Fp>\n\u003Cp>Before releasing production, the fabricator&#39;s map, physical mark and assembler&#39;s programmed position should agree. Record the panel ID, panel and program revisions, reference view, verification result and approver. Check at least the excluded position and an adjacent intended-good position so an inverted or shifted mapping is more likely to be caught. Repeat the relevant verification after a program, panel revision or orientation change.\u003C\u002Fp>\n\u003Ch2 id=\"check-every-applicable-operation-not-only-placement\" data-anchor-en=\"check-every-applicable-operation-not-only-placement\">Check every applicable operation, not only placement\u003C\u002Fh2>\n\u003Cp>The assembler should review the complete route for the job. Machine vision, manual entry and electronic maps are possible controls, but the actual equipment and approved procedure determine which are supported and how their results are checked. Do not assume that a placement machine&#39;s skip setting also controls a printer, inspection machine or test fixture.\u003C\u002Fp>\n\u003Ctable>\n\u003Cthead>\n\u003Ctr>\n\u003Cth>Operation\u003C\u002Fth>\n\u003Cth>Question to resolve before production\u003C\u002Fth>\n\u003C\u002Ftr>\n\u003C\u002Fthead>\n\u003Ctbody>\u003Ctr>\n\u003Ctd>Receiving and setup\u003C\u002Ftd>\n\u003Ctd>Do the panel ID, drawing and required mark and\u002For map agree? Is the X-out panel segregated as required?\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Paste printing and dispensing\u003C\u002Ftd>\n\u003Ctd>Can rejected sites be excluded? If material is applied anyway, is that explicitly accepted and controlled in the process?\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Placement, on each side\u003C\u002Ftd>\n\u003Ctd>How is the skip entered or detected, and how is the physical position verified after rotation or flip?\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Inspection and electrical or functional test\u003C\u002Ftd>\n\u003Ctd>How will the systems distinguish an intentionally skipped position from an unexpected failure or missing assembly?\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003Ctr>\n\u003Ctd>Depaneling and packing\u003C\u002Ftd>\n\u003Ctd>How are rejected positions kept separate and prevented from mixing with accepted units after panel identity is lost?\u003C\u002Ftd>\n\u003C\u002Ftr>\n\u003C\u002Ftbody>\u003C\u002Ftable>\n\u003Cp>Use a controlled first-panel or other agreed verification to demonstrate the actual line behavior before the full run. Capture which stations and sides were checked, program revisions, result and approval. The \u003Ca href=\"\u002Fen\u002Fblog\u002Fassembly-drawing-essentials\">assembly drawing essentials\u003C\u002Fa> and \u003Ca href=\"\u002Fen\u002Fblog\u002Fboard-handling-and-depanelization\">board handling and depanelization\u003C\u002Fa> guides cover adjacent documentation and separation decisions.\u003C\u002Fp>\n\u003Ch2 id=\"stop-on-ambiguous-or-conflicting-information\" data-anchor-en=\"stop-on-ambiguous-or-conflicting-information\">Stop on ambiguous or conflicting information\u003C\u002Fh2>\n\u003Cp>Hold the affected panel when a required mark is missing or unreadable, a required map is absent, a supplied map is associated with the wrong ID, the count exceeds the approved allowance, or orientation cannot be established. The same applies when a mark and map disagree or a machine cannot reliably recognize the agreed mark. Do not treat an unrecognized mark as an unmarked good board.\u003C\u002Fp>\n\u003Cp>Segregate the panel and notify the designated quality contact. Obtain corrected evidence or an authorized disposition, update the applicable map and program, and verify the correction before release. A decision might be to reject the panel, replace it, or process it under a separately approved method; the authority and commercial consequences should be agreed in advance. Maintain a record of the decision and affected panel IDs.\u003C\u002Fp>\n\u003Cp>A new defect discovered during assembly is a separate event from the fabricator&#39;s original X-out. Identify its physical position, record the operation and disposition, and update downstream controls so later stations do not rely on a stale map.\u003C\u002Fp>\n\u003Ch2 id=\"reconcile-quantities-and-commercial-terms\" data-anchor-en=\"reconcile-quantities-and-commercial-terms\">Reconcile quantities and commercial terms\u003C\u002Fh2>\n\u003Cp>Write the order in terms both parties can count. State the required number of \u003Cstrong>accepted bare-board units\u003C\u002Fstrong>, the number of positions per panel and whether the quoted quantity refers to panels, gross positions or accepted units. Specify the evidence needed for acceptance and how held or disputed positions are counted.\u003C\u002Fp>\n\u003Cp>Also agree on overage, replacement or credit for shortfalls, shipping of replacement panels, invoice basis, lead-time impact and approval authority. PCBasic&#39;s published example describes one supplier&#39;s replacement approach; it is not a general promise. Ask each supplier to confirm its own terms in the quotation and purchase order.\u003C\u002Fp>\n\u003Cp>Keep a separate assembly reconciliation: accepted bare boards released to assembly, subsequent assembly rejects and rework, held units, and accepted finished assemblies. For example, if the hypothetical panel&#39;s 11 accepted bare boards all enter assembly and one later becomes assembly scrap, there are 10 remaining candidates for finished acceptance. Final output still depends on the required inspection and test results. The later assembly loss does not change the original one-position fabrication X-out count.\u003C\u002Fp>\n\u003Ch2 id=\"x-out-handoff-checklist\" data-anchor-en=\"x-out-handoff-checklist\">X-out handoff checklist\u003C\u002Fh2>\n\u003Cul>\n\u003Cli>State whether X-outs are prohibited, allowed within explicit limits, or subject to deviation approval.\u003C\u002Fli>\n\u003Cli>Attach the approved panel drawing and position convention, including each side&#39;s view and flip or rotation.\u003C\u002Fli>\n\u003Cli>Define the required physical mark and\u002For position map, panel identification, segregation and required test evidence.\u003C\u002Fli>\n\u003Cli>Confirm the skip and verification method for each applicable station and both assembly sides.\u003C\u002Fli>\n\u003Cli>Assign the hold, notification, correction and release process for missing, unreadable or conflicting information.\u003C\u002Fli>\n\u003Cli>Agree on accepted bare-board quantity, shortfall remedy, invoicing and the separate reconciliation of assembly losses.\u003C\u002Fli>\n\u003C\u002Ful>\n\u003Cp>For a project discussion, provide the panel drawing, order quantity, acceptance requirements and intended assembly route through the \u003Ca href=\"\u002Fen\u002Fquote\">quote page\u003C\u002Fa>. APTPCB offers PCB fabrication and \u003Ca href=\"\u002Fen\u002Fpcba\u002Fturnkey-assembly\">turnkey PCB assembly\u003C\u002Fa>; confirm the marking, skip controls and handling method available for the specific project before production.\u003C\u002Fp>\n\u003Cdiv data-component=\"BlogQuickQuoteInline\">\u003C\u002Fdiv>\n\n\u003C!-- faq:start -->\n\u003Ch2 id=\"frequently-asked-questions\" data-anchor-en=\"frequently-asked-questions\">Frequently asked questions\u003C\u002Fh2>\n\u003Ch3 id=\"does-an-x-out-mean-the-rest-of-the-panel-passed-electrical-test\" data-anchor-en=\"does-an-x-out-mean-the-rest-of-the-panel-passed-electrical-test\">Does an X-out mean the rest of the panel passed electrical test?\u003C\u002Fh3>\n\u003Cp>No. It identifies an excluded position. The status of the other positions depends on the inspection and test requirements and their associated records.\u003C\u002Fp>\n\u003Ch3 id=\"can-an-operator-simply-ignore-the-crossed-out-board\" data-anchor-en=\"can-an-operator-simply-ignore-the-crossed-out-board\">Can an operator simply ignore the crossed-out board?\u003C\u002Fh3>\n\u003Cp>Only if the approved process actually controls every relevant operation. A visible mark may help a person, but automated equipment and later steps need their own verified instructions.\u003C\u002Fp>\n\u003Ch3 id=\"does-accepting-x-outs-always-reduce-the-total-project-cost\" data-anchor-en=\"does-accepting-x-outs-always-reduce-the-total-project-cost\">Does accepting X-outs always reduce the total project cost?\u003C\u002Fh3>\n\u003Cp>No. Compare actual fabrication quotes and delivery terms with any assembly setup, handling and inspection costs. The result depends on the project and suppliers.\u003C\u002Fp>\n\u003C!-- faq:end -->\n\u003Csection class=\"related-links\" aria-label=\"Related\">\u003Ch3>Related links\u003C\u002Fh3>\u003Cul>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fpanelization-for-assembly\">panelization for assembly guide\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fpcb-traceability-lot-control\">lot traceability guide\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fassembly-drawing-essentials\">assembly drawing essentials\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fblog\u002Fboard-handling-and-depanelization\">board handling and depanelization\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fquote\">quote page\u003C\u002Fa>\u003C\u002Fli>\u003Cli>\u003Ca href=\"\u002Fen\u002Fpcba\u002Fturnkey-assembly\">turnkey PCB assembly\u003C\u002Fa>\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fsection>",[14,17,20,23,26,29,32,35],{"id":15,"text":16},"decide-the-acceptance-policy-before-fabrication","Decide the acceptance policy before fabrication",{"id":18,"text":19},"agree-on-a-mark-and-a-position-map","Agree on a mark and a position map",{"id":21,"text":22},"a-worked-handoff-for-a-12-position-panel","A worked handoff for a 12-position panel",{"id":24,"text":25},"check-every-applicable-operation-not-only-placement","Check every applicable operation, not only placement",{"id":27,"text":28},"stop-on-ambiguous-or-conflicting-information","Stop on ambiguous or conflicting information",{"id":30,"text":31},"reconcile-quantities-and-commercial-terms","Reconcile quantities and commercial terms",{"id":33,"text":34},"x-out-handoff-checklist","X-out handoff checklist",{"id":36,"text":37},"frequently-asked-questions","Frequently asked questions",[39,40,41,42],"PCB panelization","X-out PCB","PCB assembly","quality control","pcb-panel-x-outs",{"blog":45,"breadcrumb":54,"faq":68},{"@context":46,"@type":47,"headline":4,"description":5,"url":48,"datePublished":6,"dateModified":6,"timeRequired":11,"keywords":49,"articleSection":7,"author":50,"publisher":53},"https:\u002F\u002Fschema.org","BlogPosting","https:\u002F\u002Faptpcb.com\u002Fen\u002Fblog\u002Fpcb-panel-x-outs","PCB panelization, X-out PCB, PCB assembly, quality control",{"@type":51,"name":52},"Organization","APTPCB",{"@type":51,"name":52},{"@context":46,"@type":55,"itemListElement":56},"BreadcrumbList",[57,62,66],{"@type":58,"position":59,"name":60,"item":61},"ListItem",1,"Home","https:\u002F\u002Faptpcb.com\u002F",{"@type":58,"position":63,"name":64,"item":65},2,"Blog","https:\u002F\u002Faptpcb.com\u002Fen\u002Fblog",{"@type":58,"position":67,"name":43,"item":48},3,{"@context":46,"@type":69,"mainEntity":70},"FAQPage",[71,77,81],{"@type":72,"name":73,"acceptedAnswer":74},"Question","Does an X-out mean the rest of the panel passed electrical test?",{"@type":75,"text":76},"Answer","No. It identifies an excluded position. The status of the other positions depends on the inspection and test requirements and their associated records.",{"@type":72,"name":78,"acceptedAnswer":79},"Can an operator simply ignore the crossed-out board?",{"@type":75,"text":80},"Only if the approved process actually controls every relevant operation. A visible mark may help a person, but automated equipment and later steps need their own verified instructions.",{"@type":72,"name":82,"acceptedAnswer":83},"Does accepting X-outs always reduce the total project cost?",{"@type":75,"text":84},"No. Compare actual fabrication quotes and delivery terms with any assembly setup, handling and inspection costs. The result depends on the project and suppliers.",{"pcbManufacturingColumns":86,"capabilityColumns":214,"resourceColumns":250,"pcbaColumns":294},[87,135,164,193],{"heading":88,"links":89},"PCB Product Families",[90,93,96,99,102,105,108,111,114,117,120,123,126,129,132],{"label":91,"path":92},"FR-4 PCB","\u002Fpcb\u002Ffr4-pcb",{"label":94,"path":95},"High-Speed PCB","\u002Fpcb\u002Fhigh-speed-pcb",{"label":97,"path":98},"Multilayer PCB","\u002Fpcb\u002Fmultilayer-pcb",{"label":100,"path":101},"HDI PCB","\u002Fpcb\u002Fhdi-pcb",{"label":103,"path":104},"Flexible PCB","\u002Fpcb\u002Fflex-pcb",{"label":106,"path":107},"Rigid Flex PCB","\u002Fpcb\u002Frigid-flex-pcb",{"label":109,"path":110},"Ceramic PCB","\u002Fpcb\u002Fceramic-pcb",{"label":112,"path":113},"Heavy Copper PCB","\u002Fpcb\u002Fheavy-copper-pcb",{"label":115,"path":116},"High Thermal PCB","\u002Fpcb\u002Fhigh-thermal-pcb",{"label":118,"path":119},"Antenna PCB","\u002Fpcb\u002Fantenna-pcb",{"label":121,"path":122},"High Frequency PCB","\u002Fpcb\u002Fhigh-frequency-pcb",{"label":124,"path":125},"Microwave PCB","\u002Fpcb\u002Fmicrowave-pcb",{"label":127,"path":128},"Metal Core PCB","\u002Fpcb\u002Fmetal-core-pcb",{"label":130,"path":131},"High-Tg PCB","\u002Fpcb\u002Fhigh-tg-pcb",{"label":133,"path":134},"Backplane PCB","\u002Fpcb\u002Fbackplane-pcb",{"sections":136},[137],{"heading":138,"links":139},"RF & Materials",[140,143,146,149,152,155,158,161],{"label":141,"path":142},"Rogers PCB","\u002Fmaterials\u002Frf-rogers",{"label":144,"path":145},"Taconic PCB","\u002Fmaterials\u002Ftaconic-pcb",{"label":147,"path":148},"Teflon PCB","\u002Fmaterials\u002Fteflon-pcb",{"label":150,"path":151},"Arlon PCB","\u002Fmaterials\u002Farlon-pcb",{"label":153,"path":154},"Megtron PCB","\u002Fmaterials\u002Fmegtron-pcb",{"label":156,"path":157},"ISOLA PCB","\u002Fmaterials\u002Fisola-pcb",{"label":159,"path":160},"Spread Glass FR-4","\u002Fmaterials\u002Fspread-glass-fr4",{"label":162,"path":163},"Impedance Control","\u002Fpcb\u002Fpcb-impedance-control",{"sections":165},[166],{"heading":167,"links":168},"Manufacturing \u002F Stackups",[169,172,175,178,181,184,187,190],{"label":170,"path":171},"Quickturn Prototypes","\u002Fpcb\u002Fquick-turn-pcb",{"label":173,"path":174},"NPI & Small Batch (PCB)","\u002Fpcb\u002Fnpi-small-batch-pcb-manufacturing",{"label":176,"path":177},"High-Volume Production","\u002Fpcb\u002Fmass-production-pcb-manufacturing",{"label":179,"path":180},"High Layer Count PCB","\u002Fpcb\u002Fhigh-layer-count-pcb",{"label":182,"path":183},"PCB Fabrication Process","\u002Fpcb\u002Fpcb-fabrication-process",{"label":185,"path":186},"Advanced PCB Manufacturing","\u002Fpcb\u002Fadvanced-pcb-manufacturing",{"label":188,"path":189},"Special PCB Manufacturing","\u002Fpcb\u002Fspecial-pcb-manufacturing",{"label":191,"path":192},"Multi-Layer Laminated Structure","\u002Fpcb\u002Fmultilayer-pcb-lamination-services",{"heading":194,"links":195},"Specialties & Resources",[196,199,202,205,208,211],{"label":197,"path":198},"PCB Design & Layout Services","\u002Fpcba\u002Fpcb-design-services",{"label":200,"path":201},"PCB Surface Finishes","\u002Fpcb\u002Fpcb-surface-finishes",{"label":203,"path":204},"PCB Drilling & Vias","\u002Fpcb\u002Fpcb-drilling",{"label":206,"path":207},"PCB Stackup","\u002Fpcb\u002Fpcb-stack-up",{"label":209,"path":210},"PCB Profiling","\u002Fpcb\u002Fpcb-profiling",{"label":212,"path":213},"Quality & Inspection","\u002Fpcb\u002Fpcb-quality",[215,220,225,230,235,240,245],{"links":216},[217],{"label":218,"path":219},"Rigid PCB Capability","\u002Fcapabilities\u002Frigid-pcb",{"links":221},[222],{"label":223,"path":224},"Rigid-Flex Capability","\u002Fcapabilities\u002Frigid-flex-pcb",{"links":226},[227],{"label":228,"path":229},"Flex PCB Capability","\u002Fcapabilities\u002Fflex-pcb",{"links":231},[232],{"label":233,"path":234},"HDI PCB Capability","\u002Fcapabilities\u002Fhdi-pcb",{"links":236},[237],{"label":238,"path":239},"Metal PCB Capability","\u002Fcapabilities\u002Fmetal-pcb",{"links":241},[242],{"label":243,"path":244},"Ceramic PCB Capability","\u002Fcapabilities\u002Fceramic-pcb",{"links":246},[247],{"label":248,"path":249},"Heavy Copper PCB Capability","\u002Fcapabilities\u002Fheavy-copper-pcb",[251,262,286],{"heading":252,"links":253},"Downloads",[254,257,260],{"label":255,"path":256},"Materials Datasheet \u002F Processing Notes","\u002Fresources\u002Fdownloads-materials",{"label":258,"path":259},"PCB DFM Guidelines","\u002Fresources\u002Fdfm-guidelines",{"label":191,"path":261},"\u002Fpcb\u002Fmulti-layer-laminated-structure",{"heading":263,"links":264},"Tools",[265,268,271,274,277,280,283],{"label":266,"path":267},"Gerber Viewer","\u002Ftools\u002Fgerber-viewer",{"label":269,"path":270},"PCB Viewer","\u002Ftools\u002Fpcb-viewer",{"label":272,"path":273},"BOM Viewer","\u002Ftools\u002Fbom-viewer",{"label":275,"path":276},"3D Viewer","\u002Ftools\u002F3d-viewer",{"label":278,"path":279},"Circuit Simulator","\u002Ftools\u002Fcircuit-simulator",{"label":281,"path":282},"Impedance Calculator","\u002Ftools\u002Fimpedance-calculator",{"label":284,"path":285},"Trace Width Calculator","\u002Ftools\u002Ftrace-width-calculator",{"heading":287,"links":288},"FAQ & Blog",[289,292],{"label":290,"path":291},"FAQ","\u002Fresources\u002Ffaq",{"label":64,"path":293},"\u002Fblog",[295,325,351,384],{"heading":296,"links":297},"Core Services",[298,301,304,307,310,313,316,319,322],{"label":299,"path":300},"Turnkey PCB Assembly","\u002Fpcba\u002Fturnkey-assembly",{"label":302,"path":303},"NPI & Small Batch PCB Assembly","\u002Fpcba\u002Fnpi-assembly",{"label":305,"path":306},"Mass Production PCB Assembly","\u002Fpcba\u002Fmass-production",{"label":308,"path":309},"Flex & Rigid-Flex PCB Assembly","\u002Fpcba\u002Fflex-rigid-flex",{"label":311,"path":312},"SMT & Through-Hole Assembly","\u002Fpcba\u002Fsmt-tht",{"label":314,"path":315},"BGA PCB Assembly","\u002Fpcba\u002Fbga-qfn-fine-pitch",{"label":317,"path":318},"Components & BOM Management","\u002Fpcba\u002Fcomponents-bom",{"label":320,"path":321},"Box Build Assembly","\u002Fpcba\u002Fbox-build-assembly",{"label":323,"path":324},"PCB Assembly Testing & Quality","\u002Fpcba\u002Ftesting-quality",{"heading":326,"links":327},"Supporting Services",[328,330,333,336,339,342,345,348],{"label":329,"path":198},"PCB Design & Layout",{"label":331,"path":332},"Every Support Touchpoint","\u002Fpcba\u002Fsupport-services",{"label":334,"path":335},"Stencil Lab","\u002Fpcba\u002Fpcb-stencil",{"label":337,"path":338},"Components Sourcing","\u002Fpcba\u002Fcomponent-sourcing",{"label":340,"path":341},"IC Programming","\u002Fpcba\u002Fic-programming",{"label":343,"path":344},"Conformal Coating","\u002Fpcba\u002Fpcb-conformal-coating",{"label":346,"path":347},"Selective Soldering","\u002Fpcba\u002Fpcb-selective-soldering",{"label":349,"path":350},"BGA Reballing","\u002Fpcba\u002Fbga-reballing",{"heading":352,"links":353},"Quality & Testing",[354,357,360,363,366,369,372,375,378,381],{"label":355,"path":356},"Quality Inspection","\u002Fpcba\u002Fquality-system",{"label":358,"path":359},"First Article Inspection (FAI)","\u002Fpcba\u002Ffirst-article-inspection",{"label":361,"path":362},"Solder Paste Inspection (SPI)","\u002Fpcba\u002Fspi-inspection",{"label":364,"path":365},"AOI Optical Inspection","\u002Fpcba\u002Faoi-inspection",{"label":367,"path":368},"X-Ray \u002F CT Inspection","\u002Fpcba\u002Fxray-inspection",{"label":370,"path":371},"ICT In-Circuit Testing","\u002Fpcba\u002Fict-test",{"label":373,"path":374},"Flying Probe Testing","\u002Fpcba\u002Fflying-probe-testing",{"label":376,"path":377},"FCT \u002F Functional Testing","\u002Fpcba\u002Ffct-test",{"label":379,"path":380},"Final Inspection & Packing","\u002Fpcba\u002Ffinal-quality-inspection",{"label":382,"path":383},"Incoming Quality Control","\u002Fpcba\u002Fincoming-quality-control",{"heading":385,"linkClass":386,"links":387},"Industry Applications (Entry)","text-nowrap",[388,391,394,397,400,403,406,409,412,415,418],{"label":389,"path":390},"Server \u002F Data Center","\u002Findustries\u002Fserver-data-center-pcb",{"label":392,"path":393},"Automotive \u002F EV","\u002Findustries\u002Fautomotive-electronics-pcb",{"label":395,"path":396},"Medical","\u002Findustries\u002Fmedical-pcb",{"label":398,"path":399},"Telecom \u002F 5G","\u002Findustries\u002Fcommunication-equipment-pcb",{"label":401,"path":402},"Aerospace & Defense","\u002Findustries\u002Faerospace-defense-pcb",{"label":404,"path":405},"Drone \u002F UAV","\u002Findustries\u002Fdrone-uav-pcb",{"label":407,"path":408},"Industrial Control & Automation","\u002Findustries\u002Findustrial-control-pcb",{"label":410,"path":411},"Power & New Energy","\u002Findustries\u002Fpower-energy-pcb",{"label":413,"path":414},"Robotics & Automation","\u002Findustries\u002Frobotics-pcb",{"label":416,"path":417},"Security \u002F Security Equipment","\u002Findustries\u002Fsecurity-equipment-pcb",{"label":419,"path":420},"PCB Industry Overview →","\u002Fpcb-industry-solutions",1794926069314]