PCB Thermal Conductivity: How to Compare Materials and Heat Paths

On this page

PCB material thermal conductivity describes how readily a specified material conducts heat; it does not, by itself, predict the temperature of a component on a finished board. Thickness, the area carrying heat, copper and vias, interfaces, and the cooling arrangement all affect the result.

When comparing two candidate materials, first identify the layer each number describes. Then ask whether changing that layer addresses a meaningful part of the heat path. A higher-conductivity dielectric may help, but a different thickness or a poor contact with the heat sink can change the outcome.

The PCB material selection guide considers the wider electrical and manufacturing trade-offs. For a deliberate thermal-isolation design, where the goal is to restrict heat flow instead of removing component heat, see low thermal conductivity stackups.

What does thermal conductivity tell you?

Thermal conductivity, usually written k and expressed in W/(m·K), is a material property used to describe conduction under stated conditions. A larger value means that a uniform piece of material conducts more heat through the same geometry for the same temperature difference, within the assumptions of the comparison.

A data-sheet value may describe a laminate, an insulating dielectric, a ceramic substrate, a metal base or another layer. It does not automatically describe a populated board. In a real PCB, heat can spread sideways through copper, travel through plated holes and insulating layers, and pass into mounting hardware or the surrounding air. Those paths have different geometries and may operate in parallel.

Direction matters. In-plane heat flow is along the board; through-plane heat flow crosses its thickness. A property measured for one direction should not be substituted for another without evidence. Similarly, a published laminate value is not automatically the effective conductivity of a finished stack containing patterned copper and vias.

How do you read a material data sheet?

Record the following before using a number in a model or comparing suppliers. Some details may require a test report or clarification from the material producer.

Check Record or ask for Why it matters
Material identity Producer, exact grade, product revision and the layer represented A resin system, an IMS dielectric and a metal base are different parts of a construction.
Reported value Unit, typical value or specified limit, and any tolerance A typical value is not automatically a guaranteed minimum for each supplied lot.
Direction and temperature Measurement direction and temperature or range, if given The relevant direction and operating temperatures may differ from the published conditions.
Test basis Method and revision, specimen preparation and construction, and reported uncertainty Results may not be directly comparable when the specimen or conditions differ.
Proposed geometry Finished layer thickness, area and copper or via features along the intended heat path A material property alone does not establish the resistance of the installed layer.
Other requirements Electrical insulation, processing, reliability and supply constraints A thermally attractive material must also work in the actual design and manufacturing process.

For example, Isola's FR408HR laminate and prepreg data sheet lists 0.4 W/(m·K) in its typical values table and identifies ASTM E1952 as the method. The table entry does not state the measurement direction, temperature or specimen conditions. Ask the producer for those details before using it for a directional or temperature-specific comparison. It is a value for that named material, not a universal FR-4 value, a finished-board rating or a purchasing guarantee. The broader FR-4 properties discussion covers other parameters that affect selection.

How does thickness change thermal resistance?

For an idealized, uniform layer with steady one-dimensional heat flow, a constant conductivity and a constant heat-flow area, the layer's thermal resistance is approximately:

R = t / (k × A)

Here R is in K/W, thickness t is in meters, conductivity k is in W/(m·K) for the direction of heat flow, and area A is in square meters. Under the same simplified conditions, the temperature difference across that layer is approximately heat-flow rate in watts × R.

Consider these hypothetical insulating layers. The values are assumptions for arithmetic, not measurements or recommendations for a product. Each is assumed to carry 5 W uniformly through 100 mm², with no parallel heat path.

Assumption Layer A Layer B
Conductivity 1 W/(m·K) 2 W/(m·K)
Thickness 0.10 mm 0.20 mm
Idealized layer resistance 1.0 K/W 1.0 K/W
Temperature difference at 5 W 5.0 °C 5.0 °C

Layer B has twice the assumed conductivity, but it is also twice as thick, so the simplified calculation gives the same layer resistance. This does not mean the complete boards will run at the same temperature. Real heat flow is not necessarily uniform: spreading changes the effective area, vias introduce other paths, and contact resistance and cooling are omitted. Thickness also affects electrical insulation and mechanical design; it cannot be selected on the thermal calculation alone.

For layer A, the assumed area is 0.0001 m² and the thickness is 0.0001 m, giving R = 0.0001 / (1 × 0.0001) = 1.0 K/W. The 5 W in this example is heat assumed to cross the layer, not necessarily the electrical input power of the device.

Where does the heat actually go?

Start at the heat-generating junction and follow the plausible routes to the environment. Depending on the package and mounting, heat may pass through the component body, attachment, copper, board layers, thermal interface material and heat sink. Some heat may also leave by other paths. The importance of each route depends on the actual assembly.

If the concern is... Investigate first A material number cannot establish
A concentrated hot spot under a package Package thermal data, attachment area, copper geometry and any permitted via layout The actual junction temperature from laminate conductivity alone.
Heat crossing an insulating layer to a metal base The specified dielectric grade, thickness, effective area and isolation requirement The complete board or assembly resistance from the metal's conductivity.
Uneven contact with a heat sink Flatness, mounting pressure, interface material and the actual contact footprint Good thermal contact simply because the substrate has a high conductivity.
High operating temperature throughout an enclosure Ambient conditions, airflow or other cooling, and heat from nearby components That changing one PCB layer will meet the final temperature target.

Texas Instruments' TIDA030 application report compares two particular inverter board constructions and illustrates that PCB geometry and the interface to the heat sink both matter. Its results belong to the described boards, components and cooling conditions; they are not a general ranking of all FR-4 and insulated metal substrate designs.

A heat sink also needs a route to reject heat to its surroundings. The PCB heat sink selection discussion addresses that separate part of the path. For solid ceramic substrates, alumina versus aluminum nitride examines the ceramic material choice and its construction trade-offs.

A practical substitution decision

Suppose a designer is offered a replacement dielectric with a higher published conductivity for an insulated metal substrate. The power device, footprint and cooling hardware are to remain the same. This is a hypothetical decision, not a measured project result.

  1. Identify both products and the reported layer. Obtain current data sheets and ask for direction, temperature, test method and whether the values are typical or specified limits.
  2. Compare the intended constructions. Check finished dielectric thickness and tolerance, metal base, copper geometry, mounting and the area under the heat source. Estimate the layer's sensitivity using consistent units and assumptions.
  3. Check constraints before approving a change. The dielectric also provides electrical insulation. Confirm the project requirements, material availability, fabrication compatibility and any other properties affected by the substitution.
  4. Model the whole assembly. Include package, attachment, board, interface and cooling conditions where relevant. Investigate other paths and uncertainties if the dielectric is not the dominant resistance.
  5. Validate the proposed build. Agree on representative operating conditions, measurement locations, the required temperature margins and acceptance criteria. A material test or simulation alone does not demonstrate the installed product's performance.

If the replacement's measurement conditions are unknown, a larger data-sheet number may be a useful lead, but it is not yet a controlled basis for approval. Resolve the missing evidence with the producer and the product team.

What should you send with an RFQ?

Provide the board drawings and proposed stackup, the heat sources and their dissipated power, package locations, expected operating environment and cooling arrangement. Identify electrical isolation requirements, mechanical and assembly constraints, and the operating temperatures or temperature margins the product must meet.

Ask the supplier to identify the proposed material and construction, data-sheet revision, finished layer thicknesses and tolerances, and any allowed substitutions. Agree which inspection records or material evidence are available and what must be approved before a change. The fabricator can assess the requested construction against an agreed manufacturing specification; the product team must define and validate the system's thermal and electrical performance unless a separate service is agreed.

Share the requirements and open material questions through the quote page or contact APTPCB.

Frequently asked questions

Is a higher-conductivity PCB material always cooler?

Not necessarily. The geometry of the layer, other heat paths, contact interfaces and cooling can limit the benefit. Compare the complete construction under the same operating conditions.

Is metal-core PCB conductivity the same as its metal base conductivity?

No. A metal-core construction includes other layers and interfaces. A bulk metal value describes the base material, not a single rating for the whole board.

Does a higher Tg mean a laminate conducts heat better?

No. Glass transition temperature and thermal conductivity describe different properties. Check each against the requirements and conditions for the proposed material.

Can thermal vias replace a heat sink?

They can provide additional paths through a board, but their effect depends on construction and connectivity. They do not by themselves establish that sufficient heat reaches or leaves the final cooling surface.

Can a data-sheet value prove that a component meets its temperature limit?

No. Use the applicable component and material data in a model of the actual assembly, and validate it under representative conditions against the product's requirements.